GE Lightspeed 64 Slice CT Scanner
The GE Lightspeed VCT 64 Slice CT scanner stands out as a leading advanced CT system in the medical industry. Renowned for its high-quality imaging capabilities, the system’s rapid acquisition speed is especially beneficial for intricate cardiac and neuro imaging procedures.
Key Features and Benefits
- High-Quality Imaging: Produces pristine images, ensuring accurate diagnoses and treatment plans.
- Optimized for Various Procedures: Especially suited for angiography, cardiac, neuro, pediatric, pulmonary, and trauma scans. It particularly excels in situations where motion-free cardiovascular images, distinct arterial phase imaging, and enhanced MultiPlanar reformats are crucial.
- State-of-the-Art Components:
- Performix Pro 8.0 MHu X-ray Tube: Ensures reliability and optimal performance.
- Volara Digital Acquisition System: Guarantees precise image capture.
- V-Res 64 Detector: Offers increased resolution for detailed insights.
- Efficiency and Convenience:
- Fast Exam Time: Reduces patient discomfort and allows for a higher patient throughput.
- 227 kg Table Weight Limit: Accommodates a wide range of patients, ensuring inclusivity.
- Seamless Clinical Workflow: Enhances productivity and user experience.
- Compact, Air-Cooled Helios Gantry: Ensures the system remains at the optimal temperature, prolonging its lifespan and reliability.
Specifications:
- Mode: Multislice
- Slices per Rotation: 64
- Rotation Speed Options (seconds):
- 0.35, 0.37, 0.4, 0.42, 0.45, 0.47, 0.5, 0.6, 0.7, 0.8, 0.9, 1.0, 2.0
- Minimum Rotation Speed: 0.4 seconds
- Gantry Diameter: 70 cm
- Temporal Resolution: 175 msec
- Maximum Beam Width: 4 cm
- Room Size Requirement (LxWxH): 20 x 11.5 x 7
- Table Specifications:
- Weight Limit: 500 lbs
- Vertical Movement Range: 43-99 cm
- Longitudinal Movement Range: 203 cm horizontal
- X-ray Generator:
- kV Range: 80-140 kVp
- Maximum Scan Range:
- 170 cm (standard)
- 200 cm (optional)
- X-ray Tube Heat Capacity: 8 MHU
- Power Requirements: 150 kVA
- Number of Slices: 64 Slice
- Field Strength: 1.5 Tesla
- Bore Size: 70 cm Open Bore Design
- Magnet Length: 137 cm
- Helium Consumption: Zero Helium boil-off technology
- Gradient Strength:
- XJ Gradients: 33 mT/m, 125 T/m/s
- XQ Gradients: 45 mT/m, 200 T/m/s
- System Length: 145 cm
- System Weight: 2.4 Tons
- CT Scanner Mode: Multislice
- Slices per Rotation: 64
Power & Capacity:
- Maximum Load Capacity:
- Standard: 181 kg
- Optional: 204 kg
- Power Requirements: 150 kVA